Ecrin v4.20 - Doc v4.20.01 - © KAPPA 1988-2011
Rubis Guided Session #5: Thermal Option
• Rub
GS05 - 2/24
B01.2 • PVT Initialization
Set the Fluid type to ‘Water’ in the PVT dialog:
Fig. B01.2 • PVT Definition
Then, click on to edit the fluid properties:
Fig. B01.3 • PVT Definition – Water properties
In the ‘Main options’ tab, set Bw and Muw to ‘constant’, set the fluid thermal conductivity
to 9.01 Btu/D/ft/°F and the fluid standard heat capacity to 1 Btu/lbm/°F.
Note:
to get consistency with the results given in this guided session, respect carefully these
settings because the thermal model is very sensitive to these parameters.
1...,392,393,394,395,396,397,398,399,400,401 403,404,405,406,407,408,409,410,411,412,...485