Transfer Method 3
In the same manner, create a new Saphir project.
In Saphir, under ‘Interpretation’ tab in the left hand bar, click on
and select the
option ‘From an opened Ecrin document’. Choose the corresponding ‘corrected production’ oil
rate to load.
Perform the same when loading pressure with
.
Choose one method and perform the data transfer to a new Saphir file.
We will then rename the Saphir file to PTA_test.ks3 and save it locally.
Of course, to finish setting up the PTA project one would need to enter the proper test and PVT
parameters, but it is not in the scope of this session.
E.7.4
Partial transfer
You may also transfer only a subset of the data.
Come back to the Diamant window and display the Pressure filtered data plot.
Select the main build-up using .
Press on
to transfer the data and specify in which session and well you want to drop the
selected data. Press 'OK' to confirm.