Ecrin v4.12 - Doc v4.12.02 - © KAPPA 1988-2009
Diamant Master Guided Session #1
•
DmmGS01 - 16/33
¾
Click on
to display the preview plot. Only the 2998 preview points are plotted and
should not be considered representative of the data.
Right-click on the gauge
and select 'Add new Filtered data' in the pop-up menu.
¾
Accept all the default settings, but this time for the interpolation interval in the 'Filters' tab
use 'Production Analysis (5 min)' and proceed with the filtration process. Since it is
production data, a resolution as fine as for the pressure is not needed.
A warning message will appear after the preload step as this real set of data starts with a
gap of more than the imposed condition (1 hour here) between the first point and the
remaining one which makes the first pre-load to fail. However it is not important as the
program will automatically switch to the next valid window of points and begin the filtering.
¾
Click on
to display the filtered data statistics. The number of production points has
been reduced to about 5500 points.
¾
Click on ‘Fltd Data’
then drag & drop the filtered data into the Oil production
.
You can change the aspect of this data set to green with a right click + properties + selection
of the Aspect button:
Click on to display the plot.